| 6.6
Lifts and platform lifts
6.6.1 Passenger lift
Passenger lifts provide access between different levels
and facilitate all users of the building to travel from
one floor to another.
The obligatory requirements for barrier free provision
of lift shall be in accordance with the Design Manual Barrier
Free Access. Best Practices are as follows.
Lift car:
The minimum internal lift car dimensions should be 1100mm
wide by 1400mm deep. A passenger lift with internal dimension
of 2000mm by 1400mm and door opening of 900mm is recommended
where possible.
Lift car that travels between two floor levels can be provided
with opposing doors to allow the wheelchair user to travel
in one direction.
The wheelchair user needs sufficient space and time to
access the lift and an unobstructed area, say 1800mm by
1800mm should be considered in front of the lift.
Use non reflective wall and ceiling finish and slip resistant
floor finish.
Control button and signal:
The provision of a large call button at foot level (6.6.1a)
in the lift lobby is recommended for people with disabilities.
Clear audio and visual signaling (6.6.1b) and messages
shall be provided.
It is very useful to provide an extended door opening control
button inside (6.6.1c) and outside the lift so that the
opening time of the doors can be extended with a single
press action for access by consecutive wheelchair users
and elderly people.
|